IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V Multiconductor Type E,X,S, LSE, LSX,T control cables

Construction

Conductor: Stranded copper conductor tin or alloy coated where necessary for the application , conductor per

ASTM or IEC 60228.

Separator tape: optional

Insulation: Ethylene propylcnc rubber EPR according to IEEE 1580 2010 Type E,Type X, S, LSE, LSX and T as

option.

Shielding: optional

Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or

TPO jacket as option (optional for Type P with HD thicknesses).

Armor: optional and shall be nonmagnetic

Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P

or TPO sheath as option (optional except for tinned copper braid armoured cables).

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.8—Typical dimensions and weights; multiconductor control 600/1000 V; type T, E, X, S, LSE, and LSX cables


Number of conductors
Conductor
AWG size
Unarmored Armored Armored and sheathed
Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

Nom. dia. (in)

Approx. weight (lb/1000 ft)
2 18 0.32 43 0.38 61 0.48 102
3 18 0.34 53 0.4 71 0.49 110
4 18 0.37 65 0.43 86 0.55 143
7 18 0.43 94 0.49 118 0.62 187
10 18 0.57 145 0.63 176 0.76 263
14 18 0.62 187 0.68 220 0.80 306
16 18 0.65 206 0.71 239 0.88 369
19 18 0.68 233 0.74 268 0.91 403
24 18 0.79 288 0.85 328 1.02 481
30 18 0.88 380 0.94 425 1.11 593
37 18 0.94 444 1.00 491 1.17 668
40 18 1.01 483 1.07 536 1.24 725
61 18 1.16 678 1.22 740 1.39 954
2 16 0.34 50 0.4 68 0.5 111
3 16 0.36 64 0.42 85 0.51 125
4 16 0.39 77 0.45 98 0.58 162
7 16 0.46 119 0.52 146 0.65 220
10 16 0.61 181 0.67 214 0.80 306
14 16 0.66 233 0.72 268 0.89 400
16 16 0.70 263 0.76 298 0.93 437
19 16 0.73 309 0.79 346 0.96 490
24 16 0.89 404 0.95 449 1.12 619
30 16 0.94 480 1 527 1.17 704
37 16 1.01 570 1.07 623 1.24 812
40 16 1.09 623 1.15 679 1.32 882
61 16 1.25 881 1.31 946 1.48 1175
7 14 0.49 164 0.55 191 0.68 268
10 14 0.65 248 0.71 281 0.88 411
14 14 0.71 329 0.77 366 0.93 497
16 14 0.74 363 0.8 400 0.97 545
19 14 0.78 439 0.84 479 1.01 630
37 14 1.08 810 1.14 866 1.31 1067
40 14 1.16 876 1.22 938 1.39 1152
61 14 1.34 1272 1.4 1343 1.57 1587

NOTE—Weights and diameters given are for cables with Type E and X insulated conductors. Cables with Type T, S, LSE, and LSX insulated conductors will vary from those sho wn